Flexible drainage pipe
Category:
Details
Soft permeable pipe:
Soft permeable pipe is supported by rust-proof spring coils to form a high-pressure soft structure, and non-woven lining filtration prevents mud and sand impurities from entering the pipe; thus achieving the effect of net water seepage. The rubber tendons make the pipe wall coating and the spring coil pipe body an organic whole, with good all-round water permeability. The infiltrated water can penetrate into the pipe smoothly, while the mud and sand impurities are blocked outside the pipe, thus achieving the purpose of water permeation, filtration, and drainage in one go.
Application areas:
Drainage of roadbed, drainage of shoulders: drainage systems of mines, ash dams of thermal power plants, and garbage disposal sites; drainage of low-lying lake wetlands, roof gardens, etc.
Soft permeable pipe product specifications
Specifications
|
Wire diameter mm
|
Spring steel wire spacing roll (number/meter)
|
Inner diameter mm
|
Standard length mm
|
Filter geotextile mm
|
Nylon line D
|
RPS-50
|
1.8
|
|
48-50
|
150-450
|
0.1-0.38
|
300-1200
|
RPS-80
|
2.5
|
35-40
|
78-50
|
50-100
|
0.1-0.38
|
300-1200
|
RPS-100
|
3
|
30-35
|
98-100
|
50-100
|
0.1-0.38
|
300-1200
|
RPS-150
|
3.5
|
20-25
|
148-150
|
6-10
|
0.1-0.38
|
300-1200
|
RPS-200
|
4.5
|
19-19
|
198-200
|
6-10
|
0.1-0.38
|
300-1200
|
Soft permeable pipe body pressure parameters and permeability performance
Pipe body pressure parameters
|
Permeability
|
||||||||
Flat rate pipe diameter
|
2%
|
3%
|
4%
|
5%
|
10%
|
Experimental project
|
Unit
|
method
|
|
50mm
|
18
|
37
|
66
|
110
|
440
|
Longitudinal tensile strength
|
Kg/5cm
|
C.H.s5610
|
≥120
|
30mm
|
39
|
84
|
154
|
229
|
480
|
Longitudinal elongation
|
%
|
C.H.s5610
|
≥20
|
100mm
|
76
|
159
|
277
|
374
|
620
|
Transverse tensile strength
|
Kg/5cm
|
L3080
|
≥90
|
150mm
|
88
|
150
|
198
|
250
|
525
|
Transverse elongation
|
%
|
L3080
|
≥20
|
20mm
|
110
|
248
|
318
|
368
|
480
|
Longitudinal tear strength
|
Kg
|
C.H.s5610
|
≥35
|
Remarks
|
|
Lateral tear strength
|
Kg
|
L3080
|
≥32
|
||||
Water permeability coefficient
|
Cm/sec
|
C.H.s5610
|
≥0.02
|
||||||
Pipe body pressure resistance parameters
|
Permeability
|
||||||||
Flatness ratio pipe diameter
|
2%
|
3%
|
4%
|
5%
|
10%
|
Experimental project
|
Unit
|
off method
|
|
50mm
|
18
|
37
|
66
|
110
|
440
|
Longitudinal tensile strength
|
Kg/5cm
|
C.H.s5610
|
≥120
|
BOmm
|
39
|
84
|
154
|
229
|
480
|
Longitudinal elongation
|
%
|
C.H.s5610
|
≥20
|
100mm
|
76
|
159
|
277
|
374
|
620
|
Transverse tensile strength
|
Kg/5cm
|
L3080
|
≥90
|
150mm
|
88
|
150
|
198
|
250
|
525
|
Transverse elongation
|
%
|
L3080
|
≥20
|
20mm
|
110
|
248
|
318
|
368
|
480
|
Longitudinal tear strength
|
Kg
|
C.H.s5610
|
≥35
|
Remarks
|
|
Lateral tear strength
|
Kg
|
L3080
|
≥32
|
||||
Water permeability coefficient
|
Cm/sec
|
C.H.s5610
|
≥0.02
|
Product Inquiry